Go


GTR 196 | Gas Transmitter


Application  

The gas transmitter ADOS GTR 196 is suitable for continuous measurement of gases in normal areas and areas where there is a risk of explosion.

By employing 5 different types of sensor, noxious, explosive and non-combustible gases and vapours can be measured.

A current signal is generated that is proportional to the measured concentration of gas, which is transmitted to an evaluation unit placed in a safe area, away from any dangers of explosion.

The type test of the explosion-protected gas transmitter, is completed by the KEMA.

Test certificate: KEMA 03 ATEX 2403 X
Degree of protection: II 2 G, Ex demb [ia] IIC T6

 

TGS sensor  

The TGS sensor contains a semiconductor sensor, which is constructed on Sn02-sintered N-substrate. When combustible or reducing gases are absorbed by the surface of the sensor, the concentration of the test gas is determined by the change in conductivity.







1 = Circuit voltage
2 = Heating voltage
3 = Load resistor
GOW sensor  

The GOW sensor functions on the principle of thermal conductivity. Two rhenium-tungsten resistors are used as a measuring element, where the comparison element is subjected to normal ambient air and the measuring element is subjected to the test gas. Any change in the concentration of gas at the measurement element causes a change in temperature, which is due to the variation of conductivity.

The resultant change in resistance is a direct measure of the gas concentration.

 

1 = Disffusion filter
2 = Test resistor
3 = Comparison resistor

Product data sheet  

Fields of Application  

  • Chemical industry
  • Manufacture of paints and varnishes
  • Plastics processing plants
  • Sewage works
  • Gas-fired boiler systems
  • Liquid gas storage houses
  • Laboratories
  • Oxygen concentration measurements
  • Refineries
  • Cold storage houses (Ammonia monitoring)
  • Paint spraying booths
  • ... and many more.
VQ sensor  

The head of the VQ sensor functions on the principle of heat reaction. When combustible or reducing gases or vapours come in contact with the measuring element, they are subjected to catalytic combustion, which causes a rise in temperature; this rise causes a change in the resistance of the measuring element which is used as a measure of the component of gas being tested.


The inert element is for compensating the temperature and conductivity of the test gas.

 

1 = Catalyzer pellistor
2 = Electric connections
3 = Inert pellistor
4 = Diffusion filter

 

TOX sensor  

The TOX sensor is a measurement system with an electro-chemical cell, where the sampled gas is measured by diffusion. In the case of oxygen measurement the oxygen content is reduced in an electrolyte, thus producing a small flow of current (electro-chemical process). At a constant air pressure, this current is directly proportional to the oxygen concentration in the sampled air.

 

 

1 = Anode
2 = Electrolyte
3 = Cathode
4 = Diffusion path
5 = Diffusion filter
6 = Test gas

The IR sensor  

The test gas flows through a measurement chamber that incorporates an IR radiating source and a two-channel infrared detector. The intensity of the infrared radiation is reduced as it passes through the gas molecules. The concentration of the gas can then be calculated by the magnitude of the reduction in intensity. Since only absorption of the wavelength (A) specific to the gas under test in relation to the wavelength (B) not absorbed by a test gas is considered, interference due to dust, ageing etc., is almost fully compensated.


1 = Infrared-radiation source
2 = Test gas
3 = Diffusion filter
4 = Infrared-detector
5 = Measurement chamber
Technical data  

Type TGS VQ GOW
Measurement method Semiconductor Heat reduction Thermal conductivity
Measurement range ppm ranges to
100 % LEL
ppm ranges to
100 % LEL
from 0-5 Vol %
to 0-100 Vol %
Percentage error of f.s.d. ±5 % ±5 % ±5 %
Temperature range -25 °C to +55 °C -25 °C to +55 °C -25 °C to +55 °C
Temperature effect 5 % 2 % 2 %
Response time (t90) approx. 20 sec. approx. 20 sec. approx. 40 sec.
Pressure effect (atm.) 1 % 1 % 1 %
Mounting position optional optional optional
Application Poisonous, combustible and explosive gases in the LEL region Poisonous, combustible and explosive gases in the LEL region Gases exhibiting substantial differences in thermal conductivity, compared to air
Versions available industrial (Al), industrial (VA)- and EX version industrial (Al), industrial (VA)- and EX version industrial (Al), industrial (VA)- and EX version
Service life of the sensor unlimited, when used for gases not causing catalytic poisoning unlimited, when used for gases not causing catalytic poisoning unlimited, when used with gases that do not attack aluminium, rhenium-tungsten or gold
Supply voltage 18 V – 30 V 18 V – 30 V 18 V – 30 V
Interfaces 3-wire techniques,
4-20 mA 
3-wire techniques,
4-20 mA 
3-wire techniques,
4-20 mA o
Protection

Ex-Version
II 2 G
Ex demb [ia] IIC T6
KEMA 03
ATEX 2403 X
II 2 G
Ex demb [ia] IIC T6
KEMA 03
ATEX 2403 X
II 2 G
Ex demb [ia] IIC T6
KEMA 03
ATEX 2403 X
Protection class IP 54 IP 54 IP 54
Dimensions
(W x H x D)
150 x 170 x 105 mm 150 x 170 x 105 mm 150 x 170 x 105 mm
Weight 2,7 kg 2,7 kg 2,7 kg

 

Type TOX IR
Measurement method Electro-chemical cell Infrared
Measurement range ppm ranges to
100 Vol %
0–100 % LEL CH4, C3H8, C2H2
0–100 Vol % CH4
0–1, 2, 3, 4, 5 Vol % CO2
Percentage error of f.s.d. ±3 % ±3 %
Temperature range -25 °C to +55 °C -25 °C to +55 °C
Temperature effect 2 % 2 %
Response time (t90) < 60 sec. < 30 sec.
Pressure effect (atm.) 1 % 1 %
Mounting position optional optional
Application O2, CO, NH3, NO2,
SO2, H2S a.o.
CH4 (Vol %; LEL)
Propane (LEL)
CO2 (Vol %)
Versions available industrial (Al), industrial (VA)-
and EX version
industrial (Al), industrial (VA)-
and EX version
Service life of the sensor 12 months to 5 years
depending on the measuring cell
approx. 5 years
Supply voltage 18 V – 30 V 18 V – 30 V
Interfaces 3-wire techniques,
4-20 mA
3-wire techniques,
4–20 mA 
Protection

Ex-Version
II 2 G
Ex demb [ia] IIC T6
KEMA 03
ATEX 2403 X
II 2 G
Ex demb [ia] IIC T6
KEMA 03
ATEX 2403 X
Protection class IP 54 IP 54
Dimensions
(W x H x D)
150 x 170 x 105 mm
150 x 200 x 105 mm (O2)
150 x 170 x 105 mm
Weight 2,7 kg 2,7 kg